Using the "At/Norm" button you can switch between Automatic trigger level selection (At) and Normal (manual) trigger level. The trigger level in automatic mode is the level during 0v crossing. The trigger level in manual mode can be set using the "Level" control located below "At/Norm." Using that control, voltages larger than the amplitude of the signal can be set, too. However, as the signal level will never reach that trigger level, the signal will not be triggered in that case. To make sure the simulation allows demonstration of this
function even for high input voltages, an algorithm has been
implemented that does not use the voltage of a signal: In the
simulation a signal is always triggered as long as the trigger
control
is rotated within a range of -90° and +90° from its center position,
outside this range it is not triggered. |